Acoustic Testing Pro Temperature Calibrator with DC Voltage

Acoustic Testing Pro Temperature Calibrator with DC Voltage (Resistance, RTD) adopts high-performance ARM microprocessor, can output DC voltage, resistance, thermocouple and RTD along with quick response and stable data.

SKU: ACTPTPC-106 Category:

Overview

Acoustic Testing Pro Temperature Calibrator with DC Voltage (Resistance, RTD) adopts high-performance ARM microprocessor, can output DC voltage, resistance, thermocouple and RTD along with quick response and stable data. It comes with a true-color TFT-LCD display; keypad and touch screen operation. It also supports high precision measurement and is easy to operate. The calibrator boasts rapid response time, stable data and high precision measurements, deeming it one of the top temperature calibrators available. It is highly cost-effective and is suitable for lab applications.

 

Features

  • DC voltage output
  • Thermocouple output
  • Resistance output
  • RTD output

 

Technical Specifications

Functions Features
DCV 100 mV,-10.00 to 110.00 mV,0.01mV,Accuracy:±0.05% Set point ±30 uV100 mV,-10.00 to 110.00 mV,0.01mV,Accuracy:±0.05% Set point ±0.3 mV
OHM 400 Ω,0.0 to 400.0 Ω,0.1Ω,Accuracy:±0.05%
Set point ±0.2 Ω
TC
T -328 °F to 752 °F(-200 °C to 400 °C),32.18 °F(0.1 °C),Accuracy:±0.05% Set Point±2 °C (<=-100 °C) ±1°C (>-100 °C)
K -328 °F to 2462 °F(-200 °C to 1350 °C),32.18 °F(0.1 °C),Accuracy:±0.05% Set Point±2 °C (<=-100 °C) ±1°C (>-100 °C)
J -328 °F to 2192 °F(-200 °C to 1200 °C),32.18 °F(0.1 °C), Accuracy:±0.05% Set Point±2 °C (<=-100 °C) ±1°C (>-100 °C)
N -328 °F to 2372 °F(-200 °C to 1300 °C),32.18 °F(0.1 °C), Accuracy:±0.05% Set Point±2 °C (<=-100 °C) ±1°C (>-100 °C)
E -328 °F to 1832 °F(-200 °C to 1000 °C),32.18 °F(0.1 °C),Accuracy:±0.05% Set Point±2 °C (<=-100 °C) ±1°C (>-100 °C)
S -4 °F to 3182 °F(-20 °C to 1750 °C),33.8 °F(1 °C),Accuracy:

±0.05 % Set point ±3 °C (<=100 °C)±2 °C (>100 °C)

R -4 °F to 3182 °F(-20 °C to 1750 °C),33.8 °F(1 °C), Accuracy:±0.05 % Set point ±3 °C (<=100 °C)±2 °C (>100 °C)
B 1112 °F to 3272 °F(600 °C to 1800 °C),33.8 °F(1 °C), Accuracy:±0.05% Setpoint ±3 °C (<=400 °C to 600 °C) ±2 °C (>600 °C)
RTD
PT100 -328 °F to 752 °F(-200 °C to 400 °C),32.18 °F(0.1 °C), Accuracy:±0.05%

Set point ±0.6 °C

CU50 -58 °F to 302 °F(-50 °C to 150 °C),32.18 °F(0.1 °C), Accuracy:±0.05%

Set point ±0.6 °C

Test Environment
Operating Temperature 59 °F to 95 °F (15 °C to 35 °C)
Humidity Range 80 % RH or less
Storage Temperature 50 °F to 104 °F (10 °C to 40 °C)
Humidity Range 10 to 90 % RH
Warm-up Time > 60 minutes
Calibration Time 12 months
General Specifications
Battery Parameters 8.4 V Li, 1400 mA rechargeable battery
Size 3.54 in x 7.68 in x 1.38 in (90 mm x 195 mm x 35 mm)
Weight Approx. 14.11 oz. (400 g)
Power Supply Input:100 – 240 V to 50/ 60 Hz 0.35 AOutput:9 V 1 A DC
Display 2.8″ true-color 16 M TFT-LCD display;Touch screen
Interface Mini-USB
Others Compatible with SCPI instruction set;Adjustable backlight; Automatic power off

Reviews

There are no reviews yet.

Be the first to review “Acoustic Testing Pro Temperature Calibrator with DC Voltage”

Your email address will not be published. Required fields are marked *