Location: 800 Battery Avenue SE Atlanta GA 30339






Acoustic Testing Pro High Precision Temperature
Acoustic Testing Pro high precision temperature adopts modularized structure to output alarm, sensor auxiliary power supply, forwarding, printing, communication, and other functions.
Overview
Acoustic Testing Pro high precision temperature adopts modularized structure to output alarm, sensor auxiliary power supply, forwarding, printing, communication, and other functions. Measurement data can be displayed in a variety of types, such as bar chart graphic display, real-time trend, historical trend memory, real-time circular chart, historical circular chart memory, alarm state display, etc. Curves and data can also be printed by small printer through RS232 port.
Features
- 7 in (177.8 mm) TFT color LCD
- Wide viewing angle
- High brightness and high contrast
- USB standard interface data export
- Using SMT technology, the design is more concise
- The 32 bit high performance and highly integrated RAM processor
- The photoelectric isolated RS 485 communication interface
- Avoids the interference between channels
- The supporting software supports PC data export and viewing
Technical Specifications
| Input Signal | RTD-Resistance bulbs 3 types (Pt100, CU50, CU100) |
| Linear DC Voltage (0 V to 5 V DC, 1 V to 5 V DC,0 V to 10 V DC) | |
| DC Current (4 mA to 20 mA, 0 mA to 10 mA) | |
| 0 mV to 20 mV, 0 mV to 60mV, 0 mV to 100 mV, 0 mV to 500 mV | |
| Accuracy | 0.2 grade when RTD, linear voltage, linear current and T.C input |
| 0.2% FS ±35.6 °F (±2.0 ℃) when T.C input with cold junction compensation by internal part of recorder | |
| Sampling Rate | ≤1 s |
| Temperature Shift Coefficient | Standard value 50 PPM |
| CMR Ratio | 85 dB to 110 dB |
| Input Independence | 0 V DC to 5 V DC and 1 V DC to 5 V DC input 500 KΩ |
| 4 mA to 20 mA input 250 KΩ | |
| 0 mA to 10 mA input 500 KΩ | |
| Other signal input 20 MΩ | |
| Isolation | Isolated voltage between channels and ground 1000 V AC
Isolated voltage between channels 400 V AC |
| Input Error Action | Max, Min, Hold |
| Power supply | 100 V AC to 240 V AC, frequency 47 Hz to 63 Hz, max power consumption 5 V A |
| 24 V DC, max power consumption 5 V A (please advise when order) | |
| Insulation | When power insulation to ground is higher than 1500 V AC, leakage current 10 mA for one minute |
| When power insulation to housing is higher than 1500 V AC, leakage current 10 mA for one minute | |
| Aux. power supply | 24 V DC, max. 40 mA for sensor and transmitters, up to 8 points built in |
| Processor | 32 bits, high performance, and integrated ARM CPU |
| Hardware guider | CPU inner integration for long time, stable and safe operation |
| Hardware Clock | Adopt hardware real clock with high stability. Clock accuracy ±5 ppm. After power off, Li battery for continual power supply |
| validity of battery is 30 days | |
| Data Memory | All data will be stored in FLASH memory, not need reserve battery to ensure that all the history data and configuration |
| parameters will be not lost when power off | |
| Comm. Port | Photoelectrical isolated RS 485 communication interface |
| Comm. Protocol | Standard MODBUS- RTU comm. protocol, can communicate with modern HMI and DCS directly |
| Printing Port | Photoelectrical isolated RS 232C print port, Baudrate 9600 bps
Maximum print resolution 240 dot per line |
| Record Time | Record time = 45 days x record interval ÷ channel numbers. Can record 1 day data at least, also for 440 years at most |
| Display | 7.0 in (177.8 mm), 320 Pixel x 240 Pixel TFT, Color LCD display |
| Ambient | Working Temperature 32 ℉ to 122 ℉ (0 ℃ to 50 ℃) Relative humidity 10% to 85% (now dew) |
| Transport and storage -4 ℉ to 140 ℉ (-20 ℃ to 60 ℃) Relative humidity 5% to 95% | |
| Size | Dimension 7.68 in x 5.70 in x 2.38 in (195 mm x 145 mm x 60.5 mm) Panel Flush Mounted |
| Net Weight | Maximum 2.2 lb (1 kg) |











Reviews