Acoustic Testing Pro temperature monitoring function calibrator can operate the measurement and source function simultaneously. The LCD screen is divided into two separate districts, whose upper part displays measurement information and lower part displays source information. TC measurement or source terminals and built-in lead connector of same temperature (RJ compensation with auto-reference joint point). Manual step source and auto-step and sweeping step-source

 

Technical Specifications

source DC millivolt Range -10 mV to 110mV
Accuracy= ± (% of the set value+% of range) 0.02%+0.01%
Resolution 1 uV
DC voltage Range -0.1 V to 11 V
Accuracy= ± (% of the set value+% of range) 0.02%+0.01%
Resolution 10 uV or 0.1 mV
DC current Range 0 mA to 22 mA
Accuracy= ± (% of the set value+% of range) 0.02%+0.02%
Resolution 1 uA
Sink current Range 0 mA to 22 mA
Accuracy= ± (% of the set value+% of range) 0.02%+0.02%
Resolution 1 uA
External power supply -5 V to 28 V
Resistance Range 0 KΩ to +40 KΩ
Accuracy= ± (% of the set value+% of range) 0.02%+0.02%
Resolution 0.01 Ω or 0.1 Ω or 1 Ω
RTD Pt 100 or Pt200 or Pt500 or Pt1000 or Cu10 or Cu50
Accuracy 32.36 °F (0.02 °C)
Resolution 32.18 °F (0.1 °C)
Frequency Range 1 Hz to 110 KHz
Accuracy ±2 words
Resolution 0.01 Hz or 1 Hz or 0.1 KHz or 2 KHz
Measure DC millivolt  Range -5 mV to 550 mV
Accuracy= ± (% of Reading+ % of Range) 0.02%+0.01%
Resolution 1 uV or 10 uV
DC voltage Range -0.5 V to 55 V
Accuracy= ± (% of Reading+ % of Range) 0.02%+0.01%
Resolution 0.1 mV or 1 mV
DC current Range -5 mA to 55 mA
Accuracy= ± (% of Reading+ % of Range) 0.02%+0.01%
Resolution 1 uA
Resistance Range 0 KΩ to 5.5 KΩ
Accuracy= ± (% of Reading+ % of Range) 0.05%+0.02%
Resolution 0.01 Ω or 0.1 Ω
RTD Range Pt100 or Pt200 or Pt500 or Pt1000 or Cu10 or Cu50
Accuracy 32.54 °F (0.3 ℃)
Resolution 32.18 °F (0.1 ℃)
Frequency Range 3 Hz to 50 KHz
Accuracy ±2 words
Resolution 0.01 Hz or 0.1 Hz or 1 Hz
Continuity beeper Range 0 Ω to 500 Ω
Accuracy ≤50 Ω sound
Resolution 0.01 Ω
Loop power supply Range 24 V
Accuracy ±10%
The maximum current 22 mA
Withstand voltage The input and output AC 350 V / 1 minutes
Insulation The input and output DC 500 V or 50 MΩ
Display Double display on the LCD screen
Power supply -4 × 1.5 V AAA Alkaline battery
Size 8.07 in x 3.74 in x 1.65 in (205 mm × 95 mm × 42 mm)
Weight 1.10 lb (500 g)