Location: 800 Battery Avenue SE Atlanta GA 30339




Acoustic Testing Pro High Performance Radiation Meter
Acoustic Testing Pro high performance radiation meter uses the powerful computing function and storage function of the microcomputer combined with the infrared CO2 analyzer, the temperature and humidity sensor and the light sensor to measure and calculate the photosynthesis, respiration, transpiration and other indicators of plants.
Features
- The photosynthesis rate analyzer is compact and lightweight
- Easy to carry around, and can be measured anytime, anywhere
- The dot matrix LCD screen is 320 x 240
- English menu displays multiple information, the cursor guides the operation
- Open-circuit measurement and closed-circuit measurement are available
- The modification date, time, leaf area, volume, etc. can be set
- The measurement process and results are displayed and stored in time
- Historical data can also be viewed on the instrument
- Data stored in host can be imported into computer for secondary analysis
- Types of leaf chambers are suitable for different measurement objects
- It can be used both indoors and outdoors
- Both in vivo and in vitro can be measured
Technical Specifications
| CO Analysis | Non-Diffusion Infrared CO2 Analysis |
| Measuring Range | 0 ppm to 1000 ppm, 0 ppm to 1500 ppm, 0 ppm to 2000 ppm Resolution 0.1 ppm Accuracy 5 ppm |
| Leaf Chamber Temperature | High-precision digital temperature sensor |
| Blade Temperature | Platinum resistance |
| Leaf Humidity | High-precision digital humidity sensor imported from Switzerland |
| Measuring Range | 0% to 100%, resolution 0.1%, error ≤ ± 3% |
| Photosynthetically Active Radiation (PAR) | Silicon Photovoltaic Cells with Corrective Filters |
| Measuring Range | 0 μmolmm / s to 2500 μmolmm / s Accuracy: ≤ 5 μmolmm / s |
| Relative Humidity | 0% to 100% (no water vapor condensation) |
| Power Supply | DC 8.4 V lithium battery, can work continuously for 7 h to 9 h |
| Data Storage | 2 GB SD card |
| Working Environment | Temperature 32 °F to 122 °F (0 °C to 50 °C) |
| Measuring Range | 32 °F to 122 °F (0 °C to 50 °C) Resolution 32.18 F (0.1 °C) Error ± 32.36 °F (0.2 °C) |
| Three Leaf Chamber Sizes | Type I (0.79 in × 0.98 in (20 mm × 25 mm)) Type II (2.17 in × 0.79 in (55 mm × 20 mm)) Type III (2.56 in × 0.39 in (65 mm × 10 mm)) |
| The Standard Size | 2.17 in × 0.79 in (55 mm × 20 mm) |
| Size | 10.24 in × 10.24 in × 5.12 in (260 mm × 260 mm × 130 mm) |
| Weight | 7.2 lb (3.2 Kg) |