This Parameter pH Meter with Two Point Calibration has a pH range of -2 pH to 20 pH, -1999.9 mV to 1999.9 mV range, and a 0 MΩ to100 resistivity.
Features
- Portable multiparameter
- Large backlit LCD display
- One to Five points push-button calibration
- Auto-buffer recognition
- Selectable pH buffer standard
- Automatic electrode slope display
- Single point offset calibration
- Relative and absolute millivolts measurement
- Accurate ORP readings
- Automatically recognize ion selective electrodes
- Direct ion concentration readout
- Selectable multiple concentration units
- Automatic calibration solution recognition
- Selectable cell constant
- Linear or pure water compensation
- Automatic Temperature Compensation
- Calibration Due Reminder
- Stability indicator automatically shows
- Auto-Hold function freezes stable
- Manual temperature calibration corrects temperature deviation
- Selectable temperature unit
- Automatic electrode diagnosis
- Expanded memory stores
- Built-in real-time clock stamps stored data
- Stored data can be transferred into computer
- USB communication interface
- Multi-mode power scheme
Technical Specifications
| PH Range | -2 pH to 20 pH |
| PH Accuracy | ±0.002 pH |
| PH Resolution | 0.1 pH, 0.01 pH, 0.001 pH, Selectable |
| Calibration Points | 1 to 5 points |
| Calibration Solutions | USA, NIST, DIN or User-defined |
| Compensation Mode | Manual or Automatic |
| MV Range | -1999.9 mV to 1999.9 mV |
| MV Accuracy | ±0.2 mV |
| MV Resolution | 0.1mV, 1mV, Selectable |
| MV Calibration Points | 1 point (Only for Relative mV mode) |
| MV Calibration Range | ±200 mV |
| lon Range | 0.001 ppm to 19999 ppm, mg/L, mol/L (Refer to the range of ISE) |
| lon Accuracy | ±0.5% F.S (Monovalent), ±1 % F.S (Divalent) |
| lon Resolution | 0.001, 0.01, 0.1, 1 |
| lon Calibration Points | 2 to 5 points |
| lon Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mg/L, mol/L |
| lon Compensation Mode | Manual or Automatic |
| Conductivity Range | 0 µS/cm to 20 µS/cm, 200 µS/cm, 2000µS/cm, 20, 200 mS/cm |
| Conductivity Accuracy | ±0.5 % F. S |
| Conductivity Calibration Points | 1 to 5 points |
| Conductivity Calibration Solutions | 10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm |
| Conductivity Compensation Modes | Linear or Pure Water |
| Conductivity Cell Constant | K=0.1, 1, 10 or User-defined |
| TDS Range | 0 ppt to100 ppt (Max. 200 ppt, depending on factor setting) |
| TDS Accuracy | ±1% F. S |
| TDS TDS Factor | 0.1 to 1.0 (Default 0.5) |
| Salinity Range | 0 ppt to 10 ppt (Max. 80 ppt) |
| Salinity Accuracy | ±1% F. S |
| Salinity Measurement Modes | Seawater or Practical Salinity |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC, 6-pin Mini Plug |
| Power Requirements | 3 V × 1.5 V “AA” Batteries |
| Battery Life | Approximately 150 hours (Turn off the backlit) |
| Ph Temperature Compensation | 32 °F to 212 °F (0 °C to 100 °C) |
| lon Temperature Compensation | 32 °F to 212 °F (0 °C to 100 °C) |
| Conductivity Temperature Compensation | 32 °F to 212 °F (0 °C to 100 °C), Manual or Automatic |
| Conductivity Temperature Coefficient | 32 °F to 50 °F (0 °C to 10 °C) |
| Temperature Range | 32 °F to 221 °F (0 °C to 105 °C) |
| Temperature Accuracy | ±0.9°F (±0.5°C) |
| Temperature Resolution | 33 °F (0.1°C) |
| Dimensions | 6.69 in x 3.34 in x 1.18 in (170 mm x 85 mm x 30 mm) |
| Weight | 0.66 lb. (300 g) |