Location: 800 Battery Avenue SE Atlanta GA 30339



Acoustic Testing Pro Hanna Dedicated Conductivity/TDS/Salinity Meter
This Dedicated Conductivity/TDS/Salinity Meter has salinity range of 0.0 to 400.0%, salinity resolution of 0.1%, and salinity accuracy of ±1%.
Technical Specifications
| EC Range | 0.00 to 29.99 vs./cm, 30.0 to 299.9 μS/cm, 300 to 2999 μS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, up to 500.0 mS/cm (absolute EC) |
| EC Resolution | 0.01 μS/cm, 0.1 μS/cm, 1 μS/cm, 0.01 mS/cm, 0.1 mS/cm |
| EC Accuracy | ±1% Of reading (±0.05 μS/cm or 1 digit, whichever is greater) |
| EC Calibration | 1 Point offset calibration (0.00 μS/cm in air), 1 point slope calibration in EC standard 84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm and 111.8 mS/cm |
| TDS Range | 0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150 to 1499 ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, up to 400.0 g/L (absolute TDS) |
| TDS Resolution | 0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L |
| TDS Accuracy | ±1% Of reading (±0.03 ppm or 1 digit, whichever is greater) |
| TDS Calibration | Through EC calibration |
| EC/TDS Temperature Compensation | Automatic 23 ºF to 212 ºF (-5 ºC to 100 ºC); NoTC – nonabsolute conductivity. |
| Temperature Correction Coefficient | 0.00 to 6.00% / ºC (for EC and TDS only). Default value is 1.90% / ºC |
| EC to TDS Conversion Factor | 0.40 to 0.80 |
| Salinity (% NaCl) Range | 0.0 to 400.0% NaCl |
| Salinity (% NaCl) Resolution | 0.1% NaCl |
| Salinity (% NaCl) Accuracy | ±1% of reading |
| Salinity (% NaCl) Calibration | Single point with HI 7037L Standard |
| Salinity (PSU) Range | 2.00 to 42.00 PSU |
| Salinity (PSU) Resolution | 0.01 PSU |
| Salinity (PSU) Accuracy | ±1% Of reading |
| Salinity Range | 0.0 to 80.0 g/L |
| Salinity Resolution (ppt) | 0.01 g/L |
| Salinity Accuracy (ppt) | ±1% Of reading |
| Temperature Range | -4.0 to 248.0 °F (-20.0 to 120.0 ºC) |
| Temperature Resolution | 0.18 ºF (0.1 ºC) |
| Temperature Accuracy | ±0.9 ºF (±0.5 ºC) |
| EC/TDS Probe | HI763100 EC/Temperature probe |
| Logging Type | Manual Log on Demand (Max. 200 logs); Manual Log on Stability (Max. 200 logs); Interval Logging 100 lots, Max. 600 logs/lot |
| Logging Memory | Up to 1000 Records |
| Connectivity | 1 Micro-USB port for charging and PC connectivity, 1 USB port for storage |
| GLP | yes |
| Battery Type/Life | Built-in rechargeable battery with up to 8 hours of continuous use |
| Power Supply | 5 V DC Adapter (included) |
| Environment | (0 ºC to 50 °C) RH max 95% non-condensing |
| Dimensions | 8 in x 5.5 in x 0.5 in (202 mm x 140 mm x 12.7 mm) |
| Weight | 8.82 lb. (250 g) |








Reviews