Technical Specifications
| EC Range | 0 μS/cm to 29.99 μS/cm, 30 μS/cm to 299.9 μS/cm, 300 μS/cm to 2999 μS/cm, 3.00 mS/cm to 29.99 mS/cm, 30.0 mS/cm to 200.0 mS/cm, up to 500.0 mS/cm |
| EC Resolution | 0.01 μS/cm, 0.1 μS/cm, 1 μS/cm, 0.01 mS/cm, 0.1 mS/cm |
| EC Accuracy | ±1% of reading (±0.05 μS/cm or 1 digit, whichever is greater) |
| EC Calibration | 1 point offset calibration (0.00 μS/cm in air), 1 point slope calibration in EC standard 84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm and 111.8 mS/cm |
| TDS Range | 0.00 ppm to 14.99 ppm (mg/L), 15.0 ppm to 149.9 ppm (mg/L), 150 ppm to 1499 ppm (mg/L), 1.50 g/L to 14.99 g/L, 15.0 g/L to 100.0 g/L, up g/L to 400.0 g/L (absolute TDS) |
| TDS Resolution | 0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L |
| TDS Accuracy | ±1% of reading (±0.03 ppm or 1 digit, whichever is greater) |
| TDS Calibration | through EC calibration |
| EC/TDS Temperature Compensation | Automatic -23 °F to 212 °F (-5 °C to 100 °C); NoTC – none absolute conductivity. |
| Temperature Correction Coefficient | 0.00 to 6.00%/°C (for EC and TDS only). Default value is 1.90%/°C |
| EC To TDS Conversion Factor | 0.40 to 0.80 (default value is 0.50) |
| Salinity (% NaCl) Range | 0.0% NaCl to 400.0% NaCl |
| Salinity (% NaCl) Resolution | 0.1% NaCl |
| Salinity (% NaCl) Accuracy | ±1% of reading |
| Salinity (% NaCl) Calibration | Single point with HI 7037L Standard |
| Salinity (PSU) Range | 2.00 PSU to 42.00 PSU |
| Salinity (PSU) Resolution | 0.01 PSU |
| Salinity (PSU) Accuracy | ±1% of reading |
| Salinity Range | 0.0 g/L to 80.0 g/L |
| Salinity Resolution (ppt) | 0.01 g/L |
| Salinity Accuracy (ppt) | ±1% of reading |
| Temperature Range | -4.0 °F to 248.0 °F (-20.0 °C to 120.0 °C) |
| Temperature Resolution | 0.1 °F (0.1 °C) |
| Temperature Accuracy | 0.1 °F (±0.5 °C) |
| EC/TDS Probe | HI 763100 EC/temperature probe |
| Logging Type | Manual Log on Demand (Max. 200 logs); Manual Log on Stability (Max. 200 logs); Interval Logging 100 lots, Max. 600 logs/lot |
| Logging Memory | Up to 1000 records |
| Connectivity | 1 micro-USB port for charging and PC connectivity, 1 USB port for storage |
| GLP | yes |
| Battery Type/Life | Built-in rechargeable battery with up to 8 hours of continuous use |
| Power Supply | 5 VDC adapter (included) |
| Environment | 32 °F to 122 °F (0 °C to 50 °C), RH max 95% non-condensing |
| Dimensions | 7.95 in × 5.51 in × 0.5 in (202 mm x 140 mm x 12.7 mm) |
| Weight | 0.55 lb. (250g) |