Location: 800 Battery Avenue SE Atlanta GA 30339




Acoustic Testing Pro Chlorine Ion Meter
This Chlorine Ion Meter has an Ion range 1 M × 10 M to 6 M, 0.02 ppm to saturation, memory stores up to 500 data sets, and an accuracy of ± 0.2 mV.
Technical Specifications
| F Ion Concentration Range | 1 M × 10 M to 6M to saturation, 0.02 ppm to saturation |
| CL Ion Concentration Range | 5 M × 10 M to 6 M to 1 M, 1.8 ppm to 35500 ppm |
| Ca Ion Concentration Range | 5 M × 10 M to 7 M to 1 M, 0.02 ppm to 4000 ppm |
| Na Ion Concentration Range | 1M ×10 M to 5 M to 1M, 0.1 ppm to 23000 ppm |
| NO3 Ion Concentration Range | 7 M ×10 M to 6 M to 1 M, 0.4 ppm to 62000 ppm |
| Br Ion Concentration Range | 5 M × 10 M to 6 M to 1 M, 0.4 ppm to 79900 ppm |
| NH4 Ion Concentration Range | 5 M × 10 M to 6 M to 1 M, 0.1 ppm to 18000 ppm |
| Cn Ion Concentration Range | 5 M × 10 M to 6 M to 0.01 M, 0.2 ppm to 260 ppm |
| Cd Ion Concentration Range | 1 M × 10 M to 6 M to 0.1 M, 0.01 ppm to 11200 ppm |
| Cu Ion Concentration Range | 1 M ×10 M to 8 M to 0.1 M, 0.006 ppm to 6400 ppm |
| I Ion Concentration Range | 5 M ×10 M to 8 M to 1 M, 0.06 ppm to 127000 ppm |
| Pb Ion Concentration Range | 1 M ×10 M to 8 M to 0.1 M, 0.2 ppm to 20700 ppm |
| Ag Ion Concentration Range | 1 M ×10 M to 7 M to 1 M, 0.01 ppm to 107900 ppm |
| K Ion Concentration Range | 1 M ×10 M to 6 M to 1 M, 0.04 ppm to 39000 ppm |
| S Ion Concentration Range | 1 M ×10 M to 7 M to 1 M, 0.003 ppm to 32100 ppm |
| NH3 Ion Concentration Range | 1 M ×10 M to 6 M to 1 M, 0.02 ppm to 17000 ppm |
| Ion Concentration Resolution | 0.001, 0.01, 0.1, 1 |
| Ion concentration Accuracy | ± 0.5 % F.S. |
| Ion Concentration Calibration Points | 2 points to 5 points |
| Ion Concentration Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 |
| mV Range | ± 1999.9 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ± 0.2 mV |
| Stability Criteria | Low or high |
| Power | 3 V × 1.5 V AA batteries or DC 5 V power adapter |
| Battery Life | Approximately 150 hours (turn off the backlight) |
| Calibration Due Alarm | 1 day to 31 days or off |
| Temperature Offset Calibration | 1 point |
| Auto-Power Off | 10 minutes, 20 minutes, or 30 minutes after the last key pressed |
| Memory | Stores up to 500 data sets |
| Output | USB communication interface |
| Temperature Range | 32 °F to 221 °F (0 °C to 105 °C) |
| Temperature Resolution | 0.1 °F (0.1 °C) |
| Temperature Accuracy | ±0.9 °F (± 0.5 °C) |
| Temperature Calibration Range | Reading ±10 °C |
| Temperature Compensation | 32 °F to 212 °F (0 °C to 100 °C), manual or automatic |
| Connector | BNC, 0.13 in (3.5 mm) jack socket |
| Display | Custom LCD (80 mm × 60 mm) |
| Dimensions | 6.69 in x 3.34 in x 1.18 in (170 mm × 85 mm × 30 mm) |
| Weight | 0.66 lb (0.3 kg) |









Reviews
There are no reviews yet.