Location: 800 Battery Avenue SE Atlanta GA 30339



Acoustic Testing Pro Benchtop Humidity Temperature Data Logger
Acoustic Testing Pro benchtop humidity temperature data logger intelligently matches a variety of sensors, including temperature sensors, humidity sensors, pressure sensors, current and voltage transmitters, liquid level sensors, flow meters, etc.
Overview
Acoustic Testing Pro benchtop humidity temperature data logger intelligently matches a variety of sensors, including temperature sensors, humidity sensors, pressure sensors, current and voltage transmitters, liquid level sensors, flow meters, etc.
Features
- 1 channel to 16 channels multi channel optional
- 7 in (177.8mm)true color TFT LCD display
- Original Signal Detection Display Design
- Built in Flash storage data protection
Technical Specifications
| Channel | 1 channel to 16 channels |
| Voltage Input | 0 V to 5 V, 1 V to 5 V,0 mV to 20 mV, 0 mV to 100 mV |
| Current Input | 0 mA to 10 mA, 4 mA to 20mA, 0 mA to 20mA |
| Resistance Input | Res |
| Thermocouple | S, B, K, T, R, E, N, J |
| Thermal Resistance | PT 100, Cu 50, G 53, Cu 100, BA 1, B A2 (Requires three wire resistance balance, lead resistance < 10 Ω) |
| Input Specifications | Full isolation universal input, Maximum support 16 analog input |
| Radiation Pyrometer | F 1, F 2 |
| Tungsten rhenium | WRe 3 25,WRe 5 26 |
| Accuracy Real time Display | ±0.2% FS, Recall Accuracy ±0.2% FS (TC should remove the cold end error) |
| Power supply | 100 V AC to 240 VAC (Rated power voltage 220 VAC) |
| Power distribution | Transmitter 24 VDC, standard ≤60 mA (can be customized) |
| Analog output | Max support 4 channel 4 mA to 20 mA, 0 mA to 20mA, 0 mA to 10mA standard current analog output, max load capacity 750 Ω |
| Output of relay alarm | Max support 6 channel relay alarm output, contact capacity 1 A at 250 V AC at 1 A at 30 V DC |
| Baud rate | 1200 bps, 4800 bps, 9600 bps, 19200 bps, 38400 bps, 57600 bps |
| Communication | RS 485, RS 232 C |
| External storage | USB 1.1 or USB 2.0 |
| Recording capacity | 64 MB or 128 MB or 192 MB or 248 MB (Flash capacity can choose) |
| Record Interval | 1 S to 240 S, Total 11 gears |
| Recorder interval | 1 s, 2 s, 4 s, 8 s, 12 s, 24 s, 36 s, 60 s, 120 s, 180 s, 240 s |
| Thermocouple CJC error | 28.4 °F to 35.6 °F (±2 ℃) |
| Clock error | ±2 s per day |
| Humidity | 0% RH to 85% RH |
| Temperature | 32 °F to 122 °F (0 ℃ to 50 ℃) |
| Dimension | 7.09 in × 3.43 in × 5.67 in (180 mm x 87 mm x 144 mm) |