Acoustic Testing Pro Multi-Parameter Benchtop pH, EC, TDS Meter

Multi-parameter Benchtop pH, EC, TDS Meter is a lab grade meter. Data storage, USB export, auto sensor ID. Rugged, waterproof design.

SKU: ACTPPHM-191 Category:

Features

  • The host with IP 67 protection rating
  • 5 in (127 mm) color screen display, interface menu design is beautiful
  • Ergonomic curve design
  • With data storage function, data export through USB interface
  • Built-in rechargeable battery and charging directly via USB
  • Automatically identify the connected sensor type
  • The sensor can be parameterized and calibrated

 

Technical Specification

pH Principle Glass electrode method
pH Measure Range 0 pH to 14 pH
pH Resolution 0.01 pH
pH Accuracy ± 0.1 pH
ORP Principle Glass electrode method
ORP Measure Range -2000 mV to 2000 mV
ORP Resolution 1 mV
ORP Accuracy ± 2 mV (Electronic component)
Conductivity Principle Conductivity cell method
Conductivity Measure Range 0 us per cm to 20000 us per cm (K=1)
Conductivity Resolution 0.1 uS per cm to 0.01 mS per cm (base on range)
Conductivity Accuracy ± 1.5 % or ± 2 us per cm, bigger one
Dissolved oxygen Principle Fluorescence method
Dissolved oxygen Measure Range 0 mg per L to 20 mg per L;
0 ppm to 20 ppm;
0 % to 200 %
Dissolved oxygen Resolution 0.1% or 0.01 mg per l
Dissolved oxygen Accuracy ± 0.3 mg per l
Turbidity Principle Light scattering
Turbidity Measure Range 0.1 NTU to 1000 NTU
Turbidity Resolution 0.01 NTU to 0.1 NTU, based on range
Turbidity Accuracy ± 5 % or 0.3 NTU bigger one
Turbidity (Total suspended

Solids)

Principle

Light scattering
Turbidity (Total suspended

Solids)

Measure Range

0.01 mg per L to 20000 mg per L0.01 mg per L to 45000 mg per L;
0.01 mg per L to 120000 mg per L
Turbidity (Total suspended

Solids)

Resolution

0.01 mg per L to 1 mg per L,
based on range
Chlorophyll Principle Fluorescence method
Chlorophyll Measure Range 0 ug per L to 500 ug per L
Chlorophyll Resolution 0.01 ug per L
Chlorophyll Accuracy ± 5 % of the signal level of 1 ppb
Chlorophyll Linearity R 2 > 0.999
Blue-green algae Principle Fluorescence method
Blue-green algae Measure Range 0 cells per mL to 300,
000 cells per mL
Blue-green algae Resolution 20 cells per mL
Blue-green algae Accuracy ± 10 % of the signal level of 1 ppb
Blue-green algae Linearity R 2 > 0.999
Type Portable
Display LCD Display
Power supply 12 V
Protection grade IP68
Power Dissipation 3 W
Temp. Principle Thermal method
Temp. Measure Range 32 °F to 140 °F (0 ℃ to 60 ℃)
Temp. Resolution 32 °F (0.01 ℃)
Temp. Accuracy 32.9 °F (± 0.5 ℃)
Measuring Temp 32 °F to 122 °F (0 ℃ to 50 ℃) (non-freezing)
Size (mm) 3.5 in x 23.6 in (9 cm x 60 cm)
Weight 6.61 lb (3 Kg)