Location: 800 Battery Avenue SE Atlanta GA 30339




Acoustic Testing Pro Portable Fluoride Chlorine Ion Meter
This Portable Fluoride Chlorine Ion Meter has mV range of -1999.9 mV to 1999.9 mV, mV accuracy of ±0.2 mV, and power of 3×1.5 V “AA” batteries.
Technical Specifications
| F Ion Concentration Range | 1×10-6 M to saturation, 0.02ppm to saturation |
| CL Ion Concentration Range | 5×10-6 to 1M, 1.8 ppm to 35500 ppm |
| Ca Ion Concentration Range | 5×10-7 to 1M, 0.02 ppm to 4000 ppm |
| Na Ion Concentration Range | 1×10-5 to 1M, 0.1 ppm to 23000ppm |
| Ion Concentration Range | 7×10-6 to 1M, 0.4 ppm to 62000ppm |
| Br Ion Concentration Range | 5×10-6 to 1M, 0.4 ppm to 79900ppm |
| NH4 Ion Concentration Range | 5×10-6 to 1M, 0.1 ppm to 18000ppm |
| Cn Ion Concentration Range | 5×10-6 to 0.01M, 0.2 ppm to 260ppm |
| Cd Ion Concentration Range | 1×10-6 to 0.1M, 0.01 ppm to 11200ppm |
| Cu Ion Concentration Range | 1×10-8 to 0.1M, 0.006 ppm to 6400ppm |
| I Ion Concentration Range | 5×10-8 to 1M, 0.06 ppm to 127000ppm |
| Pb Ion Concentration Range | 1×10-8 to 0.1M, 0.2 ppm to 20700ppm |
| Ag Ion Concentration Range | 1×10-7 to 1M, 0.01 ppm to 107900ppm |
| K Ion Concentration Range | 1×10-6 to 1M, 0.04 ppm to 39000ppm |
| S Ion Concentration Range | 1×10-7 to 1M, 0.003 ppm to 32100ppm |
| NH3 Ion Concentration Range | 1×10-6 to 1M, 0.02 ppm to 17000ppm |
| Ion Concentration Resolution | 0.001, 0.01, 0.1, 1 |
| Ion concentration Accuracy | ±0.5% F.S. |
| Ion Concentration Calibration Points | 2 to 5 points |
| Ion Concentration Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 |
| Ion Concentration Measurement Units | ppm, mg/L, mol/L, mmol/L |
| mV Range | ±1999.9 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.2 mV |
| Temperature Range | 32 °F to 221 °F (0 °C to 105°C) |
| Temperature Resolution | 0.18°F (0.1 °C) |
| Temperature Accuracy | ±0.9 °F (±0.5 °C) |
| Temperature Offset Calibration | 1 point |
| Temperature Calibration Range | Reading 50 °F (±10 °C) |
| Temperature Compensation | 32 °F to 212°F (0 °C to 100°C), manual or automatic |
| Stability Criteria | Low or high |
| Calibration Due Alarm | 1 to 31 days or off |
| Auto-Power Off | 10, 20 or 30 minutes after last key pressed |
| Memory | Stores up to 500 data sets |
| Output | USB communication interface |
| Connector | BNC, 3.5 mm jack socket |
| Display | Custom LCD (80 mm x 60mm) |
| Power | 3×1.5 V AA batteries or DC 5 V power adapter |
| Battery Life | Approximately 150 hours (turn off the backlight) |
| Temperature Range | 32 °F to 221° F (0 °C to 105°C) |
| Dimensions | 6.69 in × 3.35 in × 1.18 in (170 mm × 85 mm × 30 mm) |
| Weight | 0.66 lb. (300 g) |









Reviews
There are no reviews yet.