Location: 800 Battery Avenue SE Atlanta GA 30339






Acoustic Testing Pro Digital Ultrasonic Flaw Detector
This Acoustic Testing Pro Digital Ultrasonic Flaw Detector has Automated gain, Peak Hold and Peak Memory with PC software and reports that can be exported to excel.
Features
- Automated calibration of transducer Zero Offset and/or Velocity.
- Automated gain, Peak Hold and Peak Memory.
- Automated display precise flaw location (Depth d, level p, distance s, amplitude sz, dB, ф).
- Automated switch three staff gauge (Depth d, level p, distance s).
- 100 independent setups, any criterion can be input freely, we can work in the scene without test block.
- Big memory of 300 A graph.
- Gate and DAC alarm; Acoustic-Optical alarm.
- RS232/USB port, communication with pc is easy.
- The embedded software can be online updated.
- Li battery, continue working time up to 10 hours.
- Display freeze.
- Automated echo degree.
- Angles and K-value.
- Lock and unlock function of system parameters.
- Dormancy and screen savers.
- Electronic clock calendar.
- Two gates setting and alarm indication.
- High-speed capture and very low noise.
- Automatically calculates the size of the flaw with wide bottom type in AVG function.
- Automatically makes video of test process and play.
- It provides high contrast viewing of the waveform from bright, direct sunlight to complete darkness and is easy to read from all angles.
- Powerful pc software and reports can be exported to excel.
Technical Specifications
| Range Of Scanning | 0 in to 590.6 in (0 mm to 15000 mm) |
| Resolution For Scanning | 0.004 in (0.1 mm): 0.1 in to 3.9 in (2.5 mm to 100 mm) 0.04 in (1 mm): 3.9 in to 196.9 in (100 mm to 5000 mm) |
| D-Delay | -20 μs to 3400 μs |
| P-Delay | 0 μs to 99.99 μs |
| Vertical Linear Error | ≤ 3% |
| Horizontal Linear Error | ≤ 0.2% |
| Working Mode | Single probe (receiving and sending), double probe (one for receiving and another for sending), transmission (transmission probe) |
| Frequency Range | 0.5 MHz to 20 MHz |
| Range Of Gain | 0 dB to 110 dB |
| Sensitivity Leavings | ≥ 62 dB |
| Dynamic Range | ≥ 34 dB |
| Alarm | Three modes, i.e. forbidden wave, loss wave and auto |
| Sound Speed | 1000 m/s to 15000m/s |
| Data Save | 300 A-Scan images (including setting of instrument) |
| Measuring Unit | mm/inch |
| Battery | Lithium battery 7.4 V 4800 mAh |
| Power Adaptor | Input 100 V to 240 V 50 Hz to 60 Hz Output 9 V DC 1.5 A |
| Working Temperature | 14 °F to 122 °F (-10 ℃ to 50 ℃) |
| Working Humidity | 20% RH to 90% RH |
| Port Type | BNC, LEMO |
| Overall Dimension | 9.45 in x 5.91 in x 1.97 in (240 mm x 150 mm x 50 mm) |
| Weight | 3.75 lbs. (1.7 kg) |











Reviews
There are no reviews yet.